The SureSigns VM series patient monitors are ideal for monitoring, recording, and alarming multiple physiological parameters of adults, pediatrics, and neonates in healthcare environments, including intra-facility transport.
Dimensions | 32 cm W x 27 cm H x 17.5 cm D (12.6" W x 10.6" H x 6.9" D)
|
Weight | 3.5 kg (7.7 lbs) excluding optional recorder and CO2
|
Screen type | 26.4 cm (10.4") SVGA TFT-AM LCD display
|
Display resolution | 800 active pixels/line, 600 active lines/frame
|
Screen active area | 211.2 mm x 158.4 mm (8.31" x 6.24")
|
Screen refresh frequency | 60
Hz
|
Pixel size | 0.264 mm (inch)
|
Viewing angle | approx. 60
°
|
Alarm Audio Range | 45 - 85
dB
|
System Response Time | 1
sec
|
Internal battery | Lithium ion, Smart battery 10.9 V to 11.1 V, 7200 mAhr
|
Battery operating time (new, fully charged) | 4
hr
|
Internal power supply | 100 to 240 VAC
|
Battery charge time | <4
hr
|
Power consumption | 72
W
|
Frequency | 50/60
Hz
|
Recorder type | Thermal
|
Paper width | 58 mm (inch)
|
User Selectable Speeds | 6.25, 12.5, 25, and 50 mm/s
|
Mechanical Shock | Complies with mechanical shock requirement in ISO 9919 standards for use within the healthcare facility.
|
Mechanical Vibration | Complies with mechanical vibration requirement in ISO 9919 standards for use within the healthcare facility.
|
Operating temperature | 10 to 40 °C (50 to 104 °F)
|
Storage temperature (device) | -20 to 50°C (-4 to 122 °F)
|
Storage temperature (device plus accessories) | -20 to 40°C (-4 to 104 °F)
|
Operating humidity | Up to 80% RH, non-condensing
|
Storage humidity | Up to 90% RH, non-condensing
|
Altitude | Up to 3000 meters above sea level
|
Heart rate range | 15 to 300
beats per minute
|
Heart rate accuracy | Greater of ±10% or ±5 bpm
|
Bandwidth (normal monitoring) | 0.67 to 40
Hz
|
Bandwidth (filtered monitoring) | 0.67 to 20
Hz
|
Leads | 3-lead and 5-lead (user-selectable)
|
Display sweep speeds | 12.5, 25, and 50 mm/s
|
Pacemaker detection | Indicator on waveform display (user-selectable)
|
ECG size (sensitivity) | 2.0, 1.0, 0.5 or 0.25 cm/mV or Auto
|
Lead Off condition | Detected and displayed
|
Input impedance | Signal reduction is less than 20% in the 0.67 to 40 Hz bandwidth
|
Input signal range | ±5
mV
|
Technique | Trans-thoracic impedance
|
Measurement range | 0 to 150
r/min
|
Accuracy | ±1 rpm in the range of 0 to 120 rpm; ±2 rpm in the range of >120 rpm
|
ECG leads used | RA to LL
|
Display sweep speeds | 6.25, 12.5, 25, or 50 mm/s
|
Lead Off condition | Detected and displayed
|
Technique | Oscillometric using stepwise deflation pressure
|
Adult measurement range - systolic | 30 mmHg to 270 mmHg (4.0 kPa to 36.0 kPa)
|
Adult measurement range - diastolic | 10 mmHg to 245 mmHg (1.3 kPa to 32.7 kPa)
|
Initial cuff inflation - Adult | 160 mmHg (21.3 kPa)
|
Adult measurement range - MAP | 20 mmHg to 255 mmHg (2.7 kPa to 34.0 kPa)
|
Adult measurement range - pulse rate | 40 to 300
beats per minute
|
Pediatric measurement range - systolic | 30 mmHg to 180 mmHg (4.0 kPa to 24.0 kPa)
|
Pediatric measurement range - diastolic | 10 mmHg to 150 mmHg (1.3 kPa to 20.0 kPa)
|
Initial cuff inflation - Pediatric | 140 mmHg (18.7 kPa)
|
Pediatric measurement range - MAP | 20 mmHg to 160 mmHg (2.7 kPa to 21.3 kPa)
|
Pediatric measurement range - pulse rate | 40 to 300
beats per minute
|
Neonatal measurement range - systolic | 30 mmHg to 130 mmHg (4.0 kPa to 17.0 kPa)
|
Neonatal measurement range - diastolic | 10 mmHg to 100 mmHg (1.3 kPa to 13.3 kPa)
|
Neonatal measurement range - MAP | 20 mmHg to 120 mmHg (2.7 kPa to 16.0 kPa)
|
Neonatal measurement range - pulse rate | 40 to 300
beats per minute
|
Blood pressure accuracy | 8 mmHg maximum standard deviation; ±5 mmHg maximum mean error
|
Pulse rate accuracy | 40 to 100 bpm: ±5 bpm; 101 to 200 bpm: ±5% of reading; 201 to 300 bpm: ±10% of reading
|
Initial cuff inflation - neonatal | 100 mmHg (13.3 kPa)
|
NBP intervals | Automatic measurements at intervals of 1, 2, 3, 5, 10, 15, 30, 60, 90, 120 minutes, and STAT
|
Measurement range | 25 to 45 °C (77 to 113 °F)
|
Accuracy | 0.1 °C to 0.2 °C (depends on probe)
°C
|
Heating/Cooling transient response time | ≤150
sec
|
Measurement range | 0 to 100
%
|
Pulse rate | 30 to 300
beats per minute
|
SpO2 accuracy | 70 to 100% (exact accuracy depends on sensor)
%
|
Pulse rate accuracy | Greater of 2% or ±1 bpm
|
Wavelength range | 500 to 1000 nm for all specified sensors
nm
|
Maximum optical output power | ≤15 mW for all specified sensors
mW
|
Measurement range | 0 to 150
mm Hg
|
Flow rate | 50, +15. -7.5
ml/min
|
CO2 waveform resolution | 0.1
mm Hg
|
etCO2, imCO2 resolution | 1.0
mm Hg
|
Initialization and power up | 40 seconds (typical); 3 minutes maximum
|
Total response time for adults | 3.9
sec
|
Maximum CO2 response time (with standard-length FilterLine) | 5.1 s (typical)
sec
|
Calibration interval | Initial calibration after 1,200 hours, then once per year or every 4,000 hours, whichever comes first
|
Auto zero interval | Once per hour (typical)
|
Leak tightness | <250 mbar/min when a 30% vacuum is invoked on the flow system
|
Accuracy | 0 mmHg to 38 mmHg: ±2 mmHg; 39 mmHg to 150 mmHg: ± (5% of reading + 0.08% for every 1 mmHg above 38 mmHg)
|
Respiration rate range | 0 to 150 breaths/min
|
Respiration accuracy | ±1 rpm in the range of 0 rpm to 70 rpm; ±2 rpm in the range of 71 rpm to 120 rpm; ±3 rpm in the range of 121 rpm to 150 rpm
|
ABP/CVP/PAP measurement range | 40 to 360
mm Hg
|
Input sensitivity | 5 μV/V/mmHg
|
Frequency response | DC to 40
Hz
|
Zero adjustment range | 200
mm Hg
|
Zero adjustment accuracy | 1
mm Hg
|
Gain accuracy | ±1
%
|
Gain accuracy drift | Less than 0.05 %/°C
|
Transducer load impedance | 200 to 2000
ohm
|
Transducer output impedance | ≤3000
ohm
|
Overall accuracy (including transducer) | Greater of ±4 mmHg or ±4%
|
Volume displacement of CPJ840J6 | 0.2 mm3/100 mmHg
|