The Lumify team is continuously working on improving Lumify, including new transducers, features The Lumify app provides imaging performance comparable to larger systems, with no compromise Scan times depend on your device, but generally, you can scan continuously for two to four hours. To see the estimated scan time for compatible devices, please visit https://www.philips.com/lumify-compatible-devices. The Lumify app requires approximately 50 MB of storage space, with additional storage space required for patient data. The Lumify transducer family has been designed and tested to meet the rigorous reliability needs of the highly mobile ultrasound market and to ensure that your transducers will survive the type of wear and impact that occurs in the highly mobile ultrasound environment. Lumify is intuitive and does not require extensive in-service training. Philips offers select point-of-care education resources at no charge, as well as more extensive education and training courses for a fee. Please visit the following websites to view all educational resources and offerings https://www.usa.philips.com/healthcare/education-resources/education-training A typical ultrasound exam with a few still images uses only about 10 MB of storage. Exams with a few three-second loops use about 50 MB. You can store hundreds of exams on any device with which Lumify is compatible (www.philips.com/Lumify-Compatible-Devices). Actual storage capacity depends on several factors, such as how much content is stored on your device. At this time, Lumify supports only Android devices. We are continually exploring opportunities to expand support for all platforms. Yes. The Patient Info form has an Accession Number field. Additionally, it can be obtained via the Modality Worklist functionality. Yes. Pediatric imaging is an indication for use. You can adjust overall gain with Lumify, and AutoScan (continuous iScan gain optimization) is always on to keep the image gain uniform from shallow to deep. Lumify captures loops (3-10 seconds in length) prospectively. Lumify starts capturing once you touch Save Loop and continues to capture until you touch Stop or until the specified loop length time expires. Philips recommends that you use a device that is listed on the tablet compatibility list:https://www.philips.com/lumify-compatible-devices Yes. XRes, the latest generation of image processing, improves image resolution and makes structures easier to visualize. Philips optimizes XRes for each clinical application. Yes. Lumify uses THI based on the clinical application. For example, on the C5-2 transducer, both the gallbladder and OB/GYN applications use THI. Yes. Lumify is a prescription medical device available for purchase by licensed medical physicians (defined as Doctor or Medicine – MD or Doctor of Osteopathic Medicine – DO) and healthcare providers that employ licensed physicians. Yes, you can configure and query a DICOM MWL server. For more information, see your Lumify User Manual. Yes. Touch Scan on the Scan/Create Yes. Two color modes are available: Fast Flow (high color scale for arterial flow) and Slow Flow (low color scale for venous flow) Yes. To view an image in full-screen view, touch [[full-screen view icon]] in the lower right corner of the image. To restore normal viewing, touch [[return to normal view icon]] See your Lumify User Manual for a full list of supported formats and for instructions on how to configure the barcode scanner. MMode is available on the S4-1, C5-2 and L12-4 transducers. Lumify is a transportable ultrasound system intended for use in environments where healthcare is provided by healthcare professionals that may include home, hospital, clinical or medical office, and transportation (EMT) environments. When you purchase Lumify outright, you get the Lumify transducer(s), the Lumify app, software upgrades, and a manufacturer's warranty. Your purchase also includes a carrying bag for your device and transducer. IMPORTANT: Your purchase does not include a compatible smart device. You can easily reset the imaging controls to the optimized defaults by reselecting the preset. This will restore depth/gains/settings to the optimized default. 27. How many linear distance measurements can I make Lumify allows a maximum of four linear distance measurements on a single image. To add a distance measurement, select Distance from the Measure menu. 28. Can I reverse the cardiac image orientation? Yes, but only for cardiac images acquired with the S4-1 transducer: touch Cardiac L/R Invert in Settings. 29. Will an automatic update to Lumify interrupt an exam? If automatic application updates are enabled in your device's Android settings, an automatic update to Lumify could interrupt system use. To avoid this situation, disable automatic updates in your Android operating system. For instructions, see the Google Play Help. 30. How does Fetal Age Summary work? In the OB/GYN preset, you can perform fetal analysis from the current exam. After freezing an image, touch Fetal Age. Touch a system-defined fetal age or growth measurement from the menu. The four fetal measurements available are HC, BPD, AC, and FL. You can also enter the LMP or EDD. As measurements are added to the Fetal Age Summary, the average fetal age is calculated based on the Hadlock 1985 published tables. After all four fetal measurements are made, the estimated fetal weight is also calculated. 31. How can I export the Fetal Age Summary? If you performed fetal age analysis, Lumify creates an image that includes a summary of the fetal measurements and calculations (the Fetal Age Summary image). The Fetal Age Summary image is included when you export the exam. 32. What is Lumify Tele-Ultrasound powered by Reacts? Lumify Integrated Tele-Ultrasound Powered by Reacts Collaborative Platform (Lumify with Reacts) is available as a subscription-based option. Reacts is interactive audio-video software developed, marketed, and sold by Innovative Imaging Technologies, Inc. (IIT). The Reacts software is integrated into the Lumify app, providing live ultrasound collaboration. 33. How do I connect with another Reacts user? Once you are logged into Reacts in the Lumify App, you can initiate a Reacts session with any of your Reacts Contacts. See User Manual for details on adding Reacts contacts and initiating sessions. 34. What's included in my Reacts subscription and how long is it valid for? For details on your Reacts plan, visit: https://reacts.com/en/plans 35. How is Patient Health Information managed while using Reacts-Tele Ultrasound? No patient data are sent to the remote user in a Reacts 36. Whom can I connect with using Reacts on my Lumify system? With your Reacts account on your Lumify system, you can connect with any Reacts user. Reacts is available as a PC client, iOS app, Web app, or within Lumify. 37. What do I need to do to get access to Reacts on my Lumify system? Before you can use Lumify with Reacts for the first time, you must be connected to the Internet and do the following: 1. Redeem or share your Reacts access codes to activate your free Reacts licenses. 2. Create a Reacts account. If you already have a Reacts account, you can use your Reacts credentials to log in to Reacts. 3. Add Reacts contacts. 38. How can I redeem or share my Reacts Tele-Ultrasound access code? With each Lumify transducer, Philips provides two access codes that, when redeemed or shared, provide free access to the Standard Plan of Reacts. See user manual for details. 39. Can I setup multiple connectivity profiles for Lumify? Connectivity profiles let you define a set of storage destinations, export strategies, exam settings, and connection settings. You can create and configure multiple connectivity profiles and quickly switch among them. You must end the exam before you can switch connectivity profiles. 40. Can I setup Lumify to delete exams after they are sent? (delete after send) The Lumify Ultrasound System is not intended for long-term storage of patient data. Export exams frequently and delete them after they are exported. 41. How do I setup a Modality Performed Procedure Step (MPPS) server? While adding a connectivity profile, under "Server & Roles", select a Modality Performed Procedure Step (MPPS) server. To add a new MPPS server, select Add New, and then, in the Setup MPPS Servers dialog box, touch Add New. See "Adding a Connectivity Profile" section of the User Manual. 42. How do I setup DICOM storage commitment server? While adding a connectivity profile, under "Server & Roles", select a DICOM storage commitment server. To add a new storage commitment server, select Manage Options and touch Add New. See "Adding a Connectivity Profile" section of the User Manual. 43. How long do I have to resume a paused exam? If you leave an exam or close the system, you can return to the open exam within 24 hours. See "Resuming Paused Exam" section of User Manual for details.1. Will you add other imaging modes such as PW Doppler?
2. How does Lumify's imaging performance compare to other systems?
3. How much usage time can I get from my Lumify system?
4. How much memory space will Lumify require?
5. How durable is the Lumify transducer?
6. What education or training is offered with Lumify?
7. What is Lumfiy's image storage capacity?
8. Does Lumify support Windows devices, such as the Surface tablet?
9. Does the Lumify patient information include accession numbers?
10. Can I use Lumify for pediatric imaging?
11. Can I
12. Is loop capture prospective or retrospective?
13. Does Lumify work with Samsung Phones (S4, S5, S6, S6 Edge)?
14. Does Lumify include XRes?
15. Does Lumify include Tissue Harmonic Imaging (THI)?
16. Does Lumify include SonoCT?
17. Will I get reimbursed for exams performed using Lumify?
Ultrasound services performed with an 18. Does Lumify support DICOM Modality Worklist (MWL)? How do I setup a Modality Worklist server?
19. Can I create temporary ID when I start an exam? If so, can I modify it with patient information later?
20. Is Color Mode available?
21. Can I scan or review images in full-screen view?
22. What barcode formats does Lumify support?
23. Which transducers is
24. Can I use Lumify outside the hospital?
25. What is included with my outright purchase of Lumify?
26. Is there a way to reset the imaging controls to the default gain/depth? Like a "reset button"?